AXB Cautions for charging N2 gas to the accumulator
-Be sure to use the 3-way valve assembly for charging the N2 gas. If charging gas leaks directly from the cylinder the diaphragm may be broken off.
-If charging for handing N2 gas to only the accumulator, make sure that the accumulator body and cover are tightened fully.
-Make sure the cap and valve of the 3-way valve assembly are fully tightened.
-Remove the cap from the accumulator and tighten the charging valve fully.
-Check if O-rings are installed to the bushing. Remove the plug and screw in the bushing.
-Install the bushing to the 3-way valve assembly.
-Loosen the charging valve gradually. The charging pressure is indicated on the pressure gauge.
-Close the valve clockwise when the gas pressure is normal. When the gas pressure is higher, repeat loosening and tightening the valve assembly. The pressure is lowered gradually.
-Loosen the valve of the 3-way valve assembly to discharge the N2 gas in the 3-way valve assembly.
-Remove the 3-way valve assembly and tighten the plug and cap.
-Charging of N2 gas into accumulator
-Connect the charging hose to N2 gas cylinder after screwing the bombe adapter on to adapter, nut and installing to the N2 gas cylinder.
-Connect the 3-way valve assembly to the charging hose after unscrewing the cap on the 3-way valve assembly.
-Remove the cap from the accumulator and tighten the charging valve fully.
-Check if O-rings are installed to the bushing. Remove the plug and screw the bushing.
-Loosen the accumulator charging valve after checking if bushing is installed to the 3-way valve assembly.
-Turn the handle of the N2 gas cylinder counter clockwise slowly to charge the gas.
-Charge the gas in accordance with the conversion table for charging N2 gas pressure to accumulator.
-Turn the handle of the N2 gas cylinder clockwise to close the cock.
-Close the accumulator charging valve.
-Loosen the valve of the 3-way valve assembly to discharge the N2 gas remaining in the charging hose.
-Remove the charging hose, 3-way valve assembly and bushing and tighten the plug and cap.